McCURDY COATINGS

Materials Selection Guide

Learn what to check for each material family. Final product, thickness and warranty come from the manufacturer's current documents and an inspection of your roof.

Read-only educational reference, not a final specification. Entries describe material families, not approved inventory. Manufacturer warranties, including NDL terms of 10 to 30 years, are subject to qualification.

Category

Elastomeric Coatings

Fluid-applied coating families used in roof restoration. Fit depends on the existing roof, water exposure, and the manufacturer's system documents.

Acrylic Coatings

Water-based elastomeric family

Family overview

Often considered for

  • Roofs that drain well
  • Many metal, concrete and previously coated surfaces, per manufacturer

What to check

Roof condition and remaining service life of the existing membraneMoisture in the roof assembly before coatingDrainage and any areas where water standsAdhesion test on a representative area

Specification review checklist

Current product rating
Confirm the current product rating (for example CRRC listing) for the exact product and date.
Specified thickness and preparation
Use the exact manufacturer thickness and surface preparation for the chosen product; do not rely on generic figures.
Warranty and assembly review
Review the manufacturer's warranty and assembly documents; terms depend on qualification.

Silicone Coatings

Silicone restoration family

Manufacturer example available

Often considered for

  • Restoration where standing water is a concern, subject to assessment
  • Roofs that pass moisture and adhesion review

What to check

Roof condition, including wet insulation or failed seamsCompatibility with the existing surface; some surfaces need a specified primerDrainage improvements versus coating over ponding areasAdhesion test before full application

Specification review checklist

Current product rating
Confirm the current product rating (for example CRRC listing) for the exact product and date.
Specified thickness and preparation
Take thickness, cleaning and primer requirements from the product's current data sheet.
Warranty and assembly review
Review the manufacturer's warranty and assembly documents; terms depend on qualification.
SOPREMA 924 ETERNA-SIL (manufacturer page)

Manufacturer example only. The page documents TRP/SOPREMA 924 ETERNA-SIL as a 100% silicone, solvent-free, high-solids, single-component moisture-cured coating and publishes current product and safety data sheets. Listing it here does not mean it is stocked, approved, or warranted for your roof.

Polyurethane and Protective Coatings

Compatibility-driven topcoat family

Family overview

Often considered for

  • Areas needing a protective or wear layer, where the system allows
  • Topcoat over a compatible base, per manufacturer

What to check

Compatibility of the protective coat with the base coating or membraneFoot traffic, chemical or wear exposureCure and recoat windows in the manufacturer documentsAdhesion test between layers

Specification review checklist

Current product rating
Confirm the current product rating (for example CRRC listing) for the exact product and date.
Specified thickness and preparation
Confirm layer-by-layer thickness and recoat requirements in the system documents.
Warranty and assembly review
Review the manufacturer's warranty and assembly documents; terms depend on qualification.
Carlisle SynTec specification supplement (manufacturer documents)

Manufacturer documents for reference only. This is not a claim that a specific Carlisle product or approval applies to your project.

Category

Specialty Systems

Spray polyurethane foam (SPF) insulation systems are offered on select projects after assessment. Ask the office whether your roof is a candidate.

SPF Insulation with Protective Coating

Foam roofing assembly

Select assessed projects

Often considered for

  • Complex roof geometry
  • Projects where added insulation is part of the plan

What to check

Roof deck condition and moisture before any foam is appliedSubstrate preparation and weather conditions at applicationDrainage and slope the foam must achieveWhich protective coating the foam manufacturer requires

Specification review checklist

Current product rating
Confirm the foam and coating ratings and code evaluations for the exact products.
Specified thickness and preparation
Foam thickness and coating thickness come from the project specification, not a general range.
Warranty and assembly review
Review the manufacturer's warranty and assembly documents; terms depend on qualification.
Category

Primers & Adhesion Promoters

Primers are chosen by substrate. The right one is set by the coating manufacturer and confirmed by an adhesion test, not by a generic list.

Substrate-Specific Primers

Metal, concrete, single-ply and aged-coating primers

Family overview

Often considered for

  • Bare or weathered metal
  • Concrete and masonry
  • Single-ply and previously coated surfaces

What to check

Substrate identification, including any prior coatingCleaning and rust or contamination treatmentPrimer named in the coating's system documents for that substrateAdhesion test result before proceeding

Specification review checklist

Current product rating
Confirm the primer is listed for your coating and substrate in current data sheets.
Specified thickness and preparation
Use the primer's stated coverage and dry time; cure windows matter.
Warranty and assembly review
Confirm the primer is part of the documented system the warranty covers.
Category

Reinforcement Fabrics

Fabrics and reinforcing details at seams, penetrations, and cracks, embedded as the coating system documents direct.

Seam and Detail Reinforcement

Polyester or fiberglass fabric with coating or mastic

Family overview

Often considered for

  • Seams and laps
  • Penetrations, curbs and parapet transitions
  • Cracks and joints that move

What to check

Which seams and details are failing and whyMovement at joints and whether reinforcement can accommodate itFabric and embedding material required by the systemFull wet-out and lap details at inspection

Specification review checklist

Current product rating
Confirm fabric and compatible detail materials in the current system documents.
Specified thickness and preparation
Specify fabric width, overlap and embedding coat thickness per the manufacturer.
Warranty and assembly review
Confirm detail work is included in the documented assembly.
Want these checks applied to your roof? Book an inspection. Final material choice, thickness and warranty are confirmed in writing against current manufacturer documents.

Need a specification reviewed for your roof?

Our team can walk through your roof's condition and the manufacturer documents with you.